Delta Inverters VFD-L Serye 1.5kW VFD015L21A
Maaari kaming Mag-supply ng mga bahagi ng Delta electric automation, tulad ng Delta PLC, Delta Servo Motor, Delta HMI, Delta VFD at iba pa,
| Mga pagtutukoy | Delta Inverters VFD-L Series | Delta Inverters VFD-L Series | ||||
| Klase ng Boltahe | 115V | 230V | ||||
| Numero ng Modelo VFD- LA/B | 004 | 002 | 004 | 007 | 015 | |
| Naaangkop na Motor Output (kW) | 0.4 | 0.2 | 0.4 | 0.7 | 1.5 | |
| Na-rate na Kapasidad ng Output (KVA) | 0.6 | 1.0 | 0.6 | 1.0 | 1.6 | 2.7 |
| Na-rate na Kasalukuyang Output (A) | 1.6 | 2.5 | 1.6 | 2.5 | 4.2 | 7.0 |
| Max. Output Voltage (V) | Ang 3-phase ay tumutugma sa dobleng boltahe ng input | Ang tatlong-phase ay tumutugma sa input boltahe | ||||
| Na-rate na Dalas (Hz) | 1.0~400Hz | |||||
| Na-rate na Input Kasalukuyang (A) | 6 | 9 | 4.9/1.9 | 6.5/2.7 | 9.7/5.1 | */9 |
| Input boltahe Tolerance | Isang yugto 90~132V 50/60Hz | Single / 3-phase 180~264V 50/60Hz | 3-phase 180~264V50/60Hz | |||
| Pagpapahintulot sa dalas | ±5% | |||||
| Sistema ng kontrol | SVPWM (Sinusoidal Pulse Width Modulation, dala dalas ng 3kHz~10kHz) | |||||
| Output Frequency Resolution | 0.1Hz | |||||
| Mga Katangian ng Torque | Kasama ang auto-torque, auto-slip compensation, starting torque ay maaaring 150% sa 5 Hz | |||||
| Overload Endurance | 150% ng kasalukuyang rate para sa 1 minuto | |||||
| Accel/Decel Time | 0.1~600Seg. (maaaring itakda nang isa-isa) | |||||
| V/F pattern | V/F pattern adjustable | |||||
| Antas ng Pag-iwas sa Stall | 20~200%, setting ng Rated Current | |||||
| Setting ng Dalas Keypad External Signal |
Pagse-set sa pamamagitan ng ▲▼ key o VR Potentiometer-5KW/0.5W, DC 0 ~ +10V (input impedance 47KW), 4~20mA (outputimpedance 250W), multi-function inputs1 hanggang 3 (3steps, JOG, UP/DOWN command), setting ng komunikasyon |
|||||
| Setting ng Operasyon Keypad |
Pagse-set sa pamamagitan ng RUN//STOP key | |||||
| Signal Panlabas na Signal |
Ang M0,M1,M2,M3 ay maaaring pagsamahin upang mag-alok ng iba't ibang mga mode ng operasyon, RS-485 communication port | |||||
| Multi-function na Input Signal | Multi-step selection 0 to 3, Jog, accel/decel inhibit, first/second accel/decel switch, counter, PLC Operation, external Base Block (NC,NO) na seleksyon | |||||
| Multi-function na Output Signal | AC Drive Operating, Frequency Attained, Non-zero speed, Base Block, Fault Indication, Local/Remote indication, PLC Operation indication. | |||||
| Iba pang Function | AVR, S-curve, Over-Voltage Stall Prevention, DC Braking, Fault Records, Adjustable Carried Frequency, Starting Frequency Setting ng DC Braking, Over-Current Stall Prevention, Pansandaliang Pagkawala ng Power restart, Reverse Inhibition, Frequency Limits, Parameter Lock/Reset | |||||
| Proteksyon | Over Voltage, Over Current, Under Voltage, Overload, Electronic thermal, Overheating, Self-testing | |||||
| Iba pa | Kasama ang EMI Filter | |||||
| Paglamig | Sapilitang pagpapalamig ng hangin | |||||
| Lokasyon ng Pag-install | Altitude 1,000 m o mas mababa, panatilihin mula sa mga nakakaagnas na gas, likido at alikabok | |||||
| Ambient Temperatura | -10 ℃-40 ℃ (Non-Condensing at hindi nagyelo) | |||||
| Temperatura ng Imbakan | -20 ℃ hanggang 60 ℃ | |||||
| Ambient Humidity | Mas mababa sa 90%RH (non-condensing) | |||||
| Panginginig ng boses | 9.80665m/s2(1G) mas mababa sa 20Hz, 5.88m/s2 (0.6Gat) 20 hanggang 50Hz |