| Availability ng Omron VFD: | |
|---|---|
Omron Inverter RX2 Series 3G3RX2-A2015 3G3RX2-A2022 3G3RX2-A2037
Maaari kaming mag-supply ng mga bahagi ng automation ng Omron tulad ng Omron PLC, Omron Servo Motor, Omron HMI, Omron VFD at Omron Relay at Omron Sensor.
100% orihinal at bagong-bago, Omron automation sa stock.
Oras ng paghahatid: Sa stock, naipadala sa loob ng 1 araw
MOQ: 1 pc
| item | Mga pagtutukoy | |
| Control mode (output sa motor) | Sine wave PWM control voltage output (line sine wave modulation) | |
| Saklaw ng dalas ng output *1 | 0.00 hanggang 590.00 Hz | |
| Katumpakan ng dalas | Digital command ±0.01% at analog command ±0.2% (25°C±10°C) laban sa maximum frequency | |
| Resolusyon ng dalas | Digital na setting: 0.01 HzAnalog setting: maximum frequency/4000 (Ai1 terminal/Ai2 terminal: 12 bit/0 to +10 V o 0 to +20 mA, Ai3 terminal 12 bit/-10 to +10 V) |
|
| Control mode (pagkalkula ng dalas/boltahe) *2 |
IM | V/f control (fixed torque/reduced torque/libre), automatic boost control, cascade model sensorless vector control, 0 Hz range sensorless vector control, vector control na may sensor. |
| Control mode (pagkalkula ng dalas/boltahe) *2 |
SM/PMM | Synchronous simula sensorless vector control, IVMS na nagsisimula ng smart sensorless vector control |
| Pabagu-bago ng bilis *3 | ±0.5% (sa panahon ng sensorless vector control) | |
| Acceleration o deceleration time | 0.00 hanggang 3600.00 sec (linear, S-shaped, U-shaped, reverse U-shaped, EL-S shaped) | |
| Display monitor | Output frequency, output current, output torque, trip history, I/O terminal status, I/O power *4, PN voltage. | |
| Pagsisimula ng mga function | Magsimula pagkatapos ng pagpepreno ng DC, pagsisimula ng pagkolekta ng dalas, pagsisimula ng frequency entrainment, pagbaba ng boltahe na pagsisimula, muling pagsisimula | |
| Paghinto ng mga function | Free-run stop, DC braking pagkatapos ng deceleration stop o terminal DC braking (braking power, operating speed adjustment) | |
| Pag-andar ng pag-iwas sa stall | Overload restraining function, overcurrent suppression function, overvoltage suppression function | |
Protektadong function *5 |
Overcurrent error, Motor overload error, Braking resister Overload error, Overvoltage error, Memory error, Undervoltage error, Current detector error, CPU error, External trip error, USP error, Ground fault error, Incoming over voltage error, Instantaneous power failure error, Temperature detector error, Cooling fan rotation speed reduction temperature error, Temperature error, Input I open-Tphase error, Input I open-Tphase error Thermistor error, Brake error, Low-speed range overload error, Controller overload error, RS485 communication error, Operator keypad disconnection error. | |
Iba pang mga pag-andar |
V/f libreng mga setting (7 puntos), Upper/lower limit frequency limiter, Frequency jump, Curve acceleration/deceleration, Manual torque boost, Energy-saving operation, Analog output adjustment function, Minimum frequency, Carrier frequency adjustment, Motor electronic thermal function (pwede rin ang libreng setting), Inverter electronic thermal function, Panlabas na pagsisimula/pagtatapos (volume/pagtatapos ng paghinto ng paghinto ng trip, Instant na pagsisimula/pagtatapos ng pag-iwas sa pag-input, Pagbabago ng dalas ng paghinto ng dalas), pagkatapos ng Frequency na paghinto ng Restart, pagkatapos ng Frequency na paghinto sa pagpili, pagkatapos signal, Mga setting ng Initialization, PID control, Awtomatikong pagbabawas ng bilis sa power shut-off, Brake control function, at Auto-tuning para sa commercial switching function (online/offline). | |