Ketersediaan: | |
---|---|
Yaskawa Sigma-7 Servopacks 1KW SGD7S-7R6A30A002
Kami dapat memasok suku cadang otomatisasi listrik Yaskawa, seperti Yaskawa Plc, Yaskawa Servo Motor & Yaskawa Servo Drive, Yaskawa VFD, Robot Yaskawa dan sebagainya.
Yaskawa sigma-7 servopacks sgd7s- | R70F | R90f | 2r1f | 2R8F | ||||||||||
Kapasitas motorik maksimum yang berlaku [KW] | 0.05 | 0.1 | 0.2 | 0.4 | ||||||||||
Arus keluaran kontinu [lengan] | 0.66 | 0.91 | 2.1 | 2.8 | ||||||||||
Arus keluaran maksimum sesaat [lengan] | 2.1 | 3.2 | 6.5 | 9.3 | ||||||||||
Catu Daya Sirkuit Utama | 100 VAC hingga 120 VAC, -15% hingga +10%, 50/60 Hz | |||||||||||||
Arus input sirkuit utama [lengan]* | 1.5 | 2.5 | 5 | 10 | ||||||||||
Kontrol Catu Daya | 100 VAC hingga 120 VAC, -15% hingga +10%, 50/60 Hz | |||||||||||||
Kapasitas Catu Daya [KVA]* | 0.2 | 0.3 | 0.6 | 1.4 | ||||||||||
Kehilangan Daya Sirkuit Utama [W] | 5.3 | 7.8 | 14.2 | 26.2 | ||||||||||
Kontrol Kehilangan Daya Sirkuit [W] | 12 | 12 | 12 | 12 | ||||||||||
Total kehilangan daya [w] | 17.3 | 19.8 | 26.2 | 38.2 | ||||||||||
Resistor regeneratif Resistensi eksternal minimum yang diijinkan [w] |
40 | 40 | 40 | 40 | ||||||||||
Kategori tegangan tegangan | AKU AKU AKU | |||||||||||||
Yaskawa sigma-7 servopacks sgd7s- | R70a | R90a | 1r6a | 2R8A | 3R8A | 5r5a | 7r6a | 120a | 180a | 200a | 330a | |||
Kapasitas motorik maksimum yang berlaku [KW] | 0.05 | 0.1 | 0.2 | 0.4 | 0.5 | 0.75 | 1.0 | 1.5 | 2.0 | 3.0 | 5.0 | |||
Arus keluaran kontinu [lengan] | 0.66 | 0.91 | 1.6 | 2.8 | 3.8 | 5.5 | 7.6 | 11.6 | 18.5 | 19.6 | 32.9 | |||
Arus keluaran maksimum sesaat [lengan] | 2.1 | 3.2 | 5.9 | 9.3 | 11 | 16.9 | 17 | 28 | 42 | 56 | 84.0 | |||
Catu daya | 200 VAC hingga 240 VAC, -15% hingga +10%, 50 Hz/60 Hz | |||||||||||||
Masukan arus [lengan]* | 0.4 | 0.8 | 1.3 | 2.5 | 3.0 | 4.1 | 5.7 | 7.3 | 10 | 15 | 25 | |||
Kontrol Catu Daya | 200 VAC hingga 240 VAC, -15% hingga +10%, 50 Hz/60 Hz | |||||||||||||
Kapasitas Catu Daya [KVA]* | 0.2 | 0.3 | 0.5 | 1.0 | 1.3 | 1.6 | 2.3 | 3.2 | 4.0 | 5.9 | 7.5 | |||
Kehilangan Daya Sirkuit Utama [W] |
5.1 | 7.3 | 13.5 | 24.0 | 20.1 | 43.8 | 53.6 | 65.8 | 111.9 | 113.8 | 263.7 | |||
Kontrol Kehilangan Daya Sirkuit [W] | 17 | 17 | 17 | 17 | 17 | 17 | 17 | 22 | 22 | 22 | 27 | |||
Kehilangan daya resistor regeneratif bawaan [W] | - - | - - | - - | - - | 8 | 8 | 8 | 10 | 16 | 16 | 36.0 | |||
Total kehilangan daya [w] | 22.1 | 24.3 | 30.5 | 41.0 | 45.1 | 68.8 | 78.6 | 97.8 | 149.9 | 151.8 | 326.7 |