| Availability: | |
|---|---|
Schneider VFD Inverter Drive ATV610 Series 0.75-160KW
Supple possumus partes Electricas Schneider, ut Schneider PLC, Schneider Servo Motor, Schneider HMI, Schneider VFD et Schneider Nullams.
| Item | Schneider VFD Inverter Drive ATV610 Series 0.75-160KW | |||
| Adscendens genus | Scrinium integration | |||
| Gradus praesidium | IP20 | |||
| Power range for 50…60 Hz line supply | Tres phases: 380 ... 480 V (kW/HP) | 0.75…90/1…120 | ||
| Tres phase: 400 V (kW) | - | |||
| Tres phase: 440 V (kW) | - | |||
| Tres pascha: 480 V (HP); | - | |||
| Tribus phase: 500 (kW) | - | |||
| Tres-phases: 600 (HP) | - | |||
| Three-phase: 690 (kW) | - | |||
| Drive | Output frequency | 0.1… 500 Hz | ||
| Imperium type | Asynchronous motricium | Standard constant torque, variabilis vexillum torque, optimized torque modus | ||
| Synchroni motricium | AM (magnes permanentis) motor, synchronus motricium gravamen | |||
| Munera | Provectus functiones | Omnes lineamenta provectarum ATV600: b Mensuratio accurata pro vigilantia systematis industriae consummatio (deviationis <5%) Installation industria b summa deprehensio b Aer embedded cum recta accessu ad systema configuratione et vigilantia b Integratio actualis curvae sentinae ad optimize systema operantem punctum b Optimized sentinam magna secundum ipsam operating punctum b Sensorless aestimari rate fluxus b mensurae signa operantes in expressit (eg m3 / h, kWh / m3) b limitatio overvoltage ad motricium terminales b Contextual accessus ad documenta technica per dynamica QR code b Continuae et historicae mensurae reales temporis cum customizable dashboards b Praedictivae et praecaventiae sustentandae functiones tracking (ex. gr. temperaturas cum PT100/1000 specillo, vigilantia ventilationis) Securus occasus coegi cognitionis pro Altivar Processus Modular egit ab 110 kW usque ad 800 kW (150…1100 HP) |
||
| Integra salus munus | 1: STO (Salve Torque Off) SIL3 | |||
| Multis fermentum celeritatum | 16 | |||
| Numerus integrated I / O * | Analog inputs | 3: Configurable ut voltage (0...10 V) vel currente (0-20 mA/4-20 mA), 2 earum inter specimina (PTC, PT100, PT1000, vel KTY84) | ||
| Digital inputs | 6: intentione 24 V c (Logica positiva vel negativa) | |||
| Digital output | - | |||
| Analog outputs | 2: Configurable as voltage (0…10 V) seu vena (0-20 mA) | |||
| Nullam outputs | 3: I with NO/NC contacts and 2 with NO contacts | |||
| Munus salus initibus | 2: Ad salutem munus STO | |||
| I / o expansion modules (libitum) | Analog inputs | 2 differentiales analogorum inputs configurabiles per programmatum voltage (0…±10 V) orcurrentes (0-20 mA/4-20 mA), vel PTC, PT100, vel PT1000, 2- vel 3-filum. | ||
| Digital inputs | 6: intentione 24 V c (Logica positiva vel negativa) | |||
| Digital outputs | II: Assignable | |||
| Nullam output modulus (libitum) | Nullam outputs | III, nulla contactus | ||
| Communicationis | Integrated | Modbus/TCP, Modbus Vide link | ||
| Option modulorum | Aer/IP, Modbus TCP et MD-Link Portus dualis, CANopen Aster catena, SUB-D et stipes cochleae, PROFINET, PROFIBUS DP V1, DeviceNet, BACnet MS/TP, POWERLINK | |||
| Configurationis et instrumenta runtime | Graphica ostentatio terminalis, infixa servo Web server, DTM (Device Type Manager), SoMovesoftware | |||
| Signa et certificaciones | 86/188/EEC, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6,EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1; TÜV certificationem, e notatione |