6DL1135-6TB00-0HX1
Siemens
The Siemens SIMATIC ET 200SP HA BU-SEND BASE BA-SEND (6DL1135-6TB00-0HX1) is a specialized Base Unit (mechanical carrier) for the ET 200SP High Availability distributed I/O system. It provides the electrical bridge for potential groups and incorporates SEND clock cycle synchronization functionality. This Base Unit is critical for achieving true high availability, as it enables hot-swapping of I/O modules without interrupting communication to the partner CPU/IO-Controller in redundant configurations. The BU-SEND ensures seamless module replacement under load, a key requirement for process industries where maintenance must not cause downtime. Used in oil & gas, chemical, and power generation plants with S7-410 redundant controllers.
Q: What is the main purpose of this Base Unit?
A: It enables hot-swapping of I/O modules without interrupting communication in redundant HA configurations.
Q: What does SEND functionality mean?
A: It supports SEND clock cycle synchronization, ensuring seamless data transfer during module replacement under load.
Q: Can I use standard Base Units instead?
A: No. Standard Base Units do not support the hot-swap and SEND features required for HA redundancy.
Q: What wiring types are available?
A: Screw-type or push-in (spring-cage) terminals, depending on the specific variant.
Q: Is this an I/O module?
A: No. It is a Base Unit (mechanical carrier) that the I/O module plugs into
FAQ
.
Siemens 6DL1135-6TB00-0HX1 | |
SIMATIC ET 200SP HA | Ex-AQ 2xI HART, suitable for BaseUnit type X1, CC51, channel diagnostics, intrinsically safe | |
Feature | Specification |
Product type designation | Ex-AQ 2xI HART |
Firmware version | V1.0 |
FW update possible | Yes |
Usable BaseUnits | BU type X1 |
I&M data | Yes; I&M0 to I&M3 |
Engineering with STEP 7 TIA Portal | V16 |
Current consumption (rated value) | 65 mA |
Number of analog outputs | 2 |
Output ranges, 0 to 20 mA | Yes; 15 bit |
Output ranges, 4 mA to 20 mA | Yes; 16 bit incl. sign |
Load impedance for current outputs, min. | 50 ohm |
Load impedance for current outputs, max. | 500 ohm |
Cycle time (all channels), min. | 3 ms |
Settling time for resistive load | 1 ms; 500 ohms |
HART protocol | Yes |
Basic error limit at 25 °C, current | 0.2 % |
Operational error limit overall temperature range, current | 0.5 %; 0...60°C: 0.3% |
Linearity error | 0.01 % |
Temperature error | 0.005 %/K |
Diagnostic alarm | Yes |
Substitute values connectable | Yes |
Wire break | Yes; From output value > 240 uA |
Short-circuit | Yes; < 20 ohms as of 1 mA output value |
Ex(i) characteristics for IIC: Uo | 22 V max. |
Ex(i) characteristics for IIC: Io | 91 mA max. |
Ex(i) characteristics for IIC: Po | 501 mW max. |
DIAG LED | Yes; green/red |
Channel status display | Yes; green LED |
Potential separation between channels and backplane bus | Yes |
Ambient temperature horizontal installation | -40 to 70 °C |
Width | 20 mm |
Height | 73 mm |
Depth | 58 mm |
Weight, approx. | 55 g |