Mitsubishi VFDs Inverter 0.75kW FR-F740-0.75K-CHT
Maaari kaming Mag-supply ng mga bahagi ng mitsubishi electric automation, tulad ng Mitsubishi PLC, Mitsubishi Servo Motor, Mitsubishi HMI, Mitsubishi VFD at iba pa,
| Mitsubishi VFDs Inverter | Mitsubishi VFDs Inverter FR-F740 Series 0.75K hanggang 90K |
| Mga Detalye ng Kontrol Sistema ng Kontrol |
High carrier frequency PWM control (V/F control)/optimum excitation control/simpleng magnetic flux vector control |
| Saklaw ng Dalas ng Output | 0.5 hanggang 400Hz |
| Resolution ng Setting ng Dalas Analog Input | 0.015Hz/0 hanggang 60Hz (terminal 2, 4: 0 hanggang 10V/12bit); 0.03Hz/0 hanggang 60Hz (terminal 2, 4: 0 hanggang 5V/11bit, 0 hanggang 20mA/approx. 11bit, terminal 1: -10V hanggang +10V/11bit); 0.06Hz/0 hanggang 60Hz (terminal 1: 0 hanggang ±5V/10bit) |
| Digital na Input | 0.01Hz |
| Katumpakan ng Dalas Analog na Input |
Sa loob ng ±0.2% ng max. dalas ng output (25°C ± 10°C) |
| Digital na Input | Sa loob ng 0.01% ng nakatakdang dalas ng output |
| Mga Katangian ng Boltahe/Dalas | Maaaring itakda ang base frequency mula 0 hanggang 400Hz. Maaaring mapili ang patuloy na torque/variable torque pattern o adjustable na 5 puntos na V/F. |
| Pagsisimula ng Torque | 120% (3Hz) kapag nakatakda sa simpleng magnetic flux vector control at slip compensation |
| Pag-set ng Oras ng Pagpapabilis/Pagbawas | 0 hanggang 3600s (maaaring isa-isang itakda ang acceleration at deceleration), linear o S-pattern na acceleration/deceleration mode |
| DC Injection Brake | Dalas ng operasyon (0 hanggang 120Hz), oras ng pagpapatakbo (0 hanggang 10s), boltahe ng operasyon (0 hanggang 30%) variable |
| Stall Prevention Operation Level | Maaaring itakda ang kasalukuyang antas ng pagpapatakbo (0 hanggang 150% adjustable), maaaring piliin kung gagamitin ang function o hindi. |
| Mga Detalye ng Operasyon Signal ng Pagtatakda ng Dalas Analog na Input |
Terminal 2, 4: 0 hanggang 10V, 0 hanggang 5V, 4 hanggang 20mA ay maaaring mapili. Terminal 1: -10 hanggang +10V, -5 hanggang 5V ay maaaring piliin. |
|
Digital na Input |
Apat na digit na BCD o 16-bit na binary gamit ang setting dial ng operation panel (kapag ginamit kasama ang opsyon na FR-A7AX) |
| Start Signal |
Magagamit nang paisa-isa para sa pasulong at pabalik na pag-ikot. Maaaring piliin ang start signal automatic self-holding input (3-wire input). |
|
Mga Signal ng Input |
Pumili ng alinmang labindalawang signal gamit ang Pr.178 hanggang Pr.189 (pagpili ng function ng terminal ng input) mula sa multi-speed selection, second function selection, terminal 4 input selection, JOG operation selection, pagpili ng awtomatikong pag-restart pagkatapos ng instantaneous power failure, external thermal relay input, HC connection (inverter operation enable signal), HC connection (instantaneous power failure operation controllock), PU signal operation over/PID interlock operation over. huminto, simulan ang self-holding selection, forward rotation command, reverse rotation command, inverter reset, PTC thermistor input, PID forward reverse operation switchover, PU-NET operation switchover, NET-external operation switchover, command source switchover. |
| Mga Pag-andar sa Pagpapatakbo |
Maximum at minimum na mga setting ng frequency, frequency jump operation, external thermal relay input selection, polarity reversible operation, automatic restart pagkatapos ng agarang power failure operation, tuluy-tuloy na operasyon sa isang instant power failure, commercial power supply-inverter switchover operation, forward/reverse rotation prevention, operation mode selection, PID control, computer link operation (RS-485). |
|
Mga Signal ng Output
Katayuan ng Operasyon |
Pumili ng alinmang pitong signal gamit ang Pr.190 hanggang Pr.196 (pagpili ng function ng terminal ng output) mula sa pagtakbo ng inverter, up-to-speed, instantaneous power failure/undervoltage, overload warning, output frequency detection, second output frequency detection, electronic thermal relay function pre-alarm, PU operation mode, inverter operation ready, output current detection, zero current limitation, PID rotation lower limit, PID rotation relay, PID rotation relay supply-inverter switchover MC1, commercial power supply-inverter switchover MC2, commercial power supply-inverter switchover MC3, fan fault output, heatsink overheat pre-alarm, inverter running start command on, deceleration at instant power failure, PID control activated, habang sinusubukang muli, sa panahon ng PID output suspension, average na pag-update ng halaga ng signal, pag-update ng power saving ng MC, average na oras ng pag-update ng signal ng kuryente 2, pagpapanatili ng timer alarma, remote output, menor de edad pagkabigo output, alarma output. Open collector output (5 points), relay output (2 points) at alarm code ng inverter ay maaaring output (4 bit) mula sa open collector. |
|
Kapag Ginamit kasama ang FR-A7AY (Option) |
Pumili ng anumang pitong signal gamit ang Pr. 313 kay Pr. 319 (extension output terminal function na seleksyon) mula sa kabilang control circuit capacitor buhay, pangunahing circuit capacitor buhay, paglamig fan buhay, inrush kasalukuyang limitasyon circuit buhay. |
| Pulse/Analog Output |
Pumili mula sa output frequency, motor current (steady o peak value), output voltage, frequency setting value, running speed, converter out-put voltage (steady o peak value), electronic thermal relay function load factor, input power, output power, load meter, reference voltage output, motor load factor, energy saving effect, PID set value, PID process value gamit ang Pr. 54 'Pagpili ng function ng terminal ng FM (pulse train output)' at Pr. 158 'Pagpili ng function ng terminal ng AM (analog output)'. |
| Display
PU (FR-DU07/ FR-PU04)
Katayuan ng Operasyon |
Output frequency, motor current (steady o peak value), output voltage, alarm indication, frequency setting, running speed, converter output voltage (steady o peak value), electronic thermal load factor, input voltage, output voltage, road meter, cumulative energization time, aktwal na tagal ng operasyon, motor load factor, cumulative energization power, power saving effect, cumulative saving power, PID deviter value set, PID deviter value set, Over saving power, PID processation set monitor, input terminal option monitor (*1), output terminal option monitor (*1), option fitting status monitor (*2), terminal assignment status (*2) |
|
Kahulugan ng Alarm |
Ipinapakita ang kahulugan ng alarm kapag na-activate ang protective function, ang output voltage/current/frequency/cumulative energization time bago na-activate ang protection function at nai-store ang nakaraang 8 alarm definition. |
|
Interactive na Patnubay |
Gabay sa operasyon/trouble shooting na may function ng tulong (*2) |
|
Proteksyon/Babala Function |
Overcurrent sa panahon ng acceleration, overcurrent sa panahon ng pare-pareho ang bilis, overcurrent sa panahon ng deceleration, overvoltage sa panahon ng acceleration, overvoltage sa panahon ng pare-pareho ang bilis, sobrang boltahe sa panahon ng deceleration, proteksyon ng inverter thermal operation, heatsink overheat, instantaneous power failure occurrence, undervoltage, input phase failure, motor overload, output side earth (ground) fault operation overcurrent, parameter ng output ng thermal fault na operasyon ng PTC, panlabas na operasyon ng alarma ng relay phase (ground) overcurrent, parameter ng output ng thermal fault na overcurrent error, PU disconnection, subukang muli ang pagbilang ng sobra, CPU alarm, power supply short para sa operation panel, 24VDC power output short, output current detection value over, inrush resistance overheat, alarm ng komunikasyon (inverter), analog input alarm, internal circuit alarm (15V power supply), fan fault, overcurrent stall prevention, overvoltage stall prevention, electronic operation prealarm, pag-iwas sa pag-iwas sa overvoltage, pagkopya ng timer ng operasyon ng alarm ( error sa pag-operate ng elektroniko, pagkopya ng parameter ng timer, error sa operasyon ng PU*1, pagkopya ng parameter ng timer, pagtigil sa operasyon ng PU*1. |
| Kapaligiran Temperatura sa paligid |
-10°C hanggang +50°C (hindi nagyeyelo) |
| Ambient Humidity |
90% RH o mas kaunti (non-condensing) |
| Temperatura ng Imbakan (*3) |
-20°C hanggang +65°C |
| Atmospera |
Sa loob ng bahay (walang corrosive gas, nasusunog na gas, oil mist, alikabok at dumi, atbp.) |