| Availability: | |
|---|---|
FU-87K FU-88 FU-88K FU-91 FU-92.
Keyence Fiber Optic Sensores
Supplere possumus omnes partes sensoriis Keyentiae, ut Keyence Digital Laser Sensores,Keyence Visio SensoriisKeyence Fiber Optic SensoresKeyence Inductiva Proximity Sensores,Keyence Photoelectrica sensoriisKeyence Positioning Sensores and So on.
| Model | FU-86H*1 |
| Axis optical diametri (Standard scopum ut detegatur) |
-1.5 mm0.059″ |
| Calor resistens temperatus | 150°F 302°F*2*3 |
| Fibra unitas longitudinis | 2 m78.74 |
| Fibra unitas diametri | 2.2 |
| Minimum flexu radii | R20 mm0.787″ |
| Minimum detectable object | Cum diametro obiecti 0.005 mm0.0002″*4 |
| Pondus | Proxime. 35 g |
| Model | FU-86Z*1 |
| Axis optical diametri (Standard scopum ut detegatur) |
ø1 mm0.039″ |
| Calor resistens temperatus | 100°F 212°F*2*3 |
| Fibra unitas longitudinis | 2 m78.74 |
| Fibra unitas diametri | 2.2 |
| Minimum flexu radii | R5 mm0.197″ Lenta-flex |
| Minimum detectable object | Cum diametro obiecti 0.005 mm0.0002″*4 |
| Pondus | Proxime. 25 g |
| Model | FU-87*1 |
| Calor resistens temperatus | 180°F 356°F*2*3 |
| Fibra unitas longitudinis | 2 m78.74 |
| Fibra unitas diametri | 2.2×2 |
| Minimum flexu radii | R35 mm1.378″ |
| Minimum detectable object | Filum aureum cum diametro 0.005 mm0.0002″ *4 |
| Pondus | Proxime. 33 g |
| Model | FU-87K*1 |
| Calor resistens temperatus | 200°F 392°F*2 |
| Fibra unitas longitudinis | I m39.37 non potest secari |
| Minimum flexu radii | R8 mm0.315″ |
| Minimum detectable object | Filum aureum cum diametro 0.005 mm0.0002″ *3 |
| Pondus | Proxime. 15 g |
| Model | FU-88*1 |
| Axis optical diametri (Standard scopum ut detegatur) |
-1.5 mm0.059″ |
| Calor resistens temperatus | 180°F 356°F*2*3 |
| Fibra unitas longitudinis | 2 m78.74 |
| Fibra unitas diametri | 2.2 |
| Minimum flexu radii | R35 mm1.378″ |
| Minimum detectable object | Cum diametro obiecti 0.005 mm0.0002″*4 |
| Pondus | Proxime. 36 g |
| Model | FU-88K*1 |
| Axis optical diametri (Standard scopum ut detegatur) |
ø1 mm0.039″ |
| Calor resistens temperatus | 200°F 392°F*2 |
| Fibra unitas longitudinis | 2 m78.74″, secari non potest |
| Minimum flexu radii | R8 mm0.315″ |
| Minimum detectable object | Cum diametro obiecti 0.005 mm0.0002″*3 |
| Pondus | Proxime. 30 g* |
| Model | FU-91*1 |
| Trabes emittens directionem | Top |
| Fibra unitas longitudinis | 2 m78.74 |
| Fibra unitas diametri | 1.3×2 |
| Minimum flexu radii | R40 mm1.575″ |
| Minimum detectable object | Filum aureum cum diametro 0.005 mm0.0002″ *2 |
| Pondus | Proxime. 32 g |
| Model | FU-92*1 |
| Axis optical diametri (Standard scopum ut detegatur) |
3.7 mm0.146″ |
| Trabes emittens directionem | Top |
| Fibra unitas longitudinis | 2 m78.74 |
| Fibra unitas diametri | 2.2 |
| Minimum flexu radii | R40 mm1.575″ |
| Minimum detectable object | Obiecto diametro 0.2 mm0.008″*2 |
| Pondus | Proxime. 71 g |