Availability: | |
---|---|
Keyence Laser Sensor LR-ZH500N LR-ZB250AN LR-ZB100N
We can Supply all kinds of Keyence sensor parts,such as Keyence Digital Laser Sensors,Keyence Vision Sensors,Keyence Fiber Optic Sensors,Keyence Inductive Proximity Sensors,Keyence Photoelectric Sensors,Keyence Positioning Sensors and So on.
Type | Distance based laser sensor | |||||
Appearance | M18 Threaded mount | Rectangular | ||||
NPN | LR-ZH490CB*1 U.C.D. Function | LR-ZB240CB | LR-ZB90CB | — | — | — |
NPN | — | — | — | LR-ZH500N U.C.D. Function | LR-ZB250AN | LR-ZB100N |
NPN | — | — | — | LR-ZH500CN U.C.D. Function | LR-ZB250CN | LR-ZB100CN |
PNP | — | — | — | LR-ZH500P*1 U.C.D. Function | LR-ZB250AP | LR-ZB100P |
PNP | — | — | — | LR-ZH500CP*1 U.C.D. Function | LR-ZB250CP | LR-ZB100CP |
PNP | — | — | — | LR-ZH500C3P*1 U.C.D. Function | LR-ZB250C3P | LR-ZB100C3P |
Detectable distance | 25 to 490 mm 0.98″ to 19.29″ (465 to 0)*2 | 25 to 240 mm 0.98″ to 9.45″(215 to 0)*2 | 25 to 90 mm 0.98″ to 3.54″(650 to 0)*2 | 35 to 500 mm 1.38″ to 19.69″(465 to 0)*2 | 35 to 250 mm 1.38″ to 9.84″(215 to 0)*2 | 35 to 100 mm 1.38″ to 3.94″(650 to 0)*2 |
Standard detectable deviation | 25 to 170 mm 0.98″ to 6.69″ : 9 mm 0.35″ 170 to 290 mm 6.69″ to 11.42″ : 25 mm 0.98″ 290 to 390 mm 11.42″ to 15.35″ : 40 mm 1.57″ 390 to 490 mm 15.35″ to 19.29″ : 50 mm 1.97″ |
25 to 170 mm 0.98″ to 6.69″ : 9 mm 0.35″ 170 to 240 mm 6.69″ to 9.45″ : 25 mm 0.98″ |
25 to 40 mm 0.98″ to 1.57″ : 1.5 mm 0.06″ 40 to 90 mm 1.57″ to 3.54″ : 3 mm 0.12″ | 35 to 180 mm 1.38″ to 7.09″ : 9 mm 0.35″ 180 to 300 mm 7.09″ to 11.81″ : 25 mm 0.98″ 300 to 400 mm 11.81″ to 15.75″ : 40 mm 1.57″ 400 to 500 mm 15.75″ to 19.69″ : 50 mm 1.97″ |
35 to 180 mm 1.38″ to 7.09″ : 9 mm 0.35″ 180 to 250 mm 7.09″ to 9.84″ : 25 mm 0.98″ |
35 to 50 mm 1.38″ to 1.97″ : 1.5 mm 0.06″ 50 to 100 mm 1.97″ to 3.94″ : 3 mm 0.12″ |
Display resolution | 1 to 5 (1 to 5 mm 0.04″ to 0.20″) | 1 to 3 (1 to 3 mm 0.04″ to 0.12) | 2 (0.2 mm 0.01″) | 1 to 5 (1 to 5 mm 0.04″ to 0.20″) | 1 to 3 (1 to 3 mm 0.04″ to 0.12″) | 2 (0.2 mm 0.01″) |
Spot size | Approx. ø3 mm ø0.12″ | Approx. 2.4 × 1.2 mm 0.09″ × 0.05″ at 240 mm 9.45″ | Approx. 2 × 1 mm 0.08″ × 0.04″ at 90 mm 3.54″ | Approx. ø3 mm ø0.12″ | Approx. 2.4 × 1.2 mm 0.09″ × 0.05″ at 250 mm 9.84″ | Approx. 2 × 1 mm 0.08″ × 0.04″ at 100 mm 3.94″ |
Response time | 1.5 ms / 10 ms / 50 ms selectable | |||||
Laser class | Class 2 laser product (IEC60825-1) Class II Laser product (FDA(CDRH) Part1040.10) | Class 1 laser product (IEC60825-1, FDA (CDRH) Part1040.10*3) | Class 2 laser product (IEC60825-1) Class II Laser product (FDA(CDRH) Part1040.10) | Class 1 laser product (IEC60825-1, FDA (CDRH) Part1040.10*3) | ||
Indicator | 3-digit 7-segment display (white), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green) | 3-digit 7-segment display (red), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green) | 3-digit 7-segment display (white), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green) | 3-digit 7-segment display (red), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green) | ||
Timer | OFF/ON delay/OFF delay/One-shot | |||||
Power voltage | 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS | |||||
Power consumption | 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) | |||||
Control output | LR-ZHxB: NPN Open collector/PNP Open collector selectable, LR-ZBxB: NPN+PNP Open collector, LR-ZxN: NPN Open collector, LR-ZxP: PNP Open collector, Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA | |||||
Protection circuit | Protection against reverse power connection, output overcurrent, output surge, reverse output connection | |||||
Output operation | Light-ON / Dark-ON selectable | |||||
External input *4 | Input time calibration: 35 ms or more ON, 35 ms or more OFF Laser emission stop: 2 ms or more ON, 20 ms or more OFF Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less |
None | Input time calibration: 35 ms or more ON, 35 ms or more OFF Laser emission stop: 2 ms or more ON, 20 ms or more OFF Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less | |||
Environmental resistance Enclosure rating | IP68(IEC60529), IP69K(DIN40050-9), NEMA 4X, 6P, 13(NEMA250), ECOLAB*5, Diversey*5 | |||||
Ambient light *6 | Incandescent lamp: 10000 lux or less Sunlight: 20000 lux or less at 240 mm 9.45″ Incandescent lamp: 2000 lux or less Sunlight: 4000 lux or less at 490mm 19.29″ | Incandescent lamp: 2000 lux or less Sunlight: 4000 lux or less | Incandescent lamp: 4000 lux or less Sunlight: 8000 lux or less | Incandescent lamp: 10000 lux or less Sunlight: 20000 lux or less at 250 mm 9.84″ Incandescent lamp: 2000 lux or less Sunlight: 4000 lux or less at 500 mm 19.69″ | Incandescent lamp: 2000 lux or less Sunlight: 4000 lux or less | Incandescent lamp: 4000 lux or less Sunlight: 8000 lux or less |
Ambient temperature | -10 to +50°C 14 to 122°F (No freezing) | |||||
Storage temperature | -25 to +75°C -13 to 167°F (No freezing) | |||||
Ambient humidity | 35 to 85%RH (No condensation) | |||||
Shock resistance | 1000 m/s2 in X, Y, Z axis directions respectively 6 times | |||||
Vibration resistance | 10 to 55 Hz Double amplitude 1.5 mm 0.06″ in the X, Y, Z axis directions respectively, 2 hours | |||||
Insulating resistance | 20 MΩ or more (500 VDC) | |||||
Withstand voltage | 1000 VAC 50/60 Hz 1 min | |||||
Material | Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM, Nut: SUS316L, Lock washer: SUS304 | Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM | ||||
Accompanying items | Instruction Manual, FDA warning/ certification/ identification label, Laser warning/explanation labels | Instruction Manual, Certification/Identification label (FDA) | Instruction Manual, FDA warning/ certification/ identification label, Laser warning/explanation labels | Instruction Manual, Certification/Identification label (FDA) |