| Availability: | |
|---|---|
Schneider VFD Inverter Drive ATV340 0.75-75KW
| Item | Schneider VFD Inverter Drive ATV340 Series 0.75-75KW | ||
| Degree of protection | IP20 | IP20 | |
| Power range for 50..60 Hz supply | Single-phase 200…240 V | 0.18…2.2 kW/0.25… 3 HP | 0.18…2.2 kW/0.25… 3 HP |
| Three-phase 200…240 V | 0.18…15 kW/0.25…20 HP | – | |
| Three-phase 380…480 V | – | ||
| Three-phase 380…500 V | 0.37…15 kW/0.5…20 HP | 0.37…15 kW/0.5…20 HP | |
| Three-phase 525…600 V | 0.75…15 kW/1…20 HP | – | |
| Drive | Output frequency | 0.1…599 Hz | – |
| Control type | Asynchronous motor
| U/F ratio (2 points, 5 points, energy saving, quadratic), flux vector control without sensor (standard and energy saving) | |
| Synchronous motor | Vector control without sensor | ||
| Motor sensor | Integrated | – | |
| Available as an option | RS422 (speed monitoring) | ||
| Overload torque performance | Up to 200% Tn of overtorque, and 170% Tn of braking torque for open loop motor control | ||
| Functions | Advanced functions | b Control of asynchronous and synchronous motors; including IE2, IE3, and PM motors in open loop b MachineStruxure integration in EcoStruxure Machine Expert b Operation in Velocity mode and Torque control (with current limitation) b Customizable and flexible application functions with ATV Logic (up to 50 function blocks) b Numerous application functions for targeted application segments b Embedded Safety functions dedicated to targeted application segments | |
| Integrated Safety functions | STO (up to SIL3/PLe), SS1, SLS, SMS, GDL | ||
| Number of preset speeds | 16 | ||
| Number of integrated I/O | Analog inputs | 3: 1 bipolar differential input ±10 V, 1 voltage input (0…10 V), and 1 current input (0-20 mA) | |
| Digital inputs | 6: 4 configurable inputs (positive or negative logic), 1 input with PTC probe, 1 x 20 kHz pulse input | ||
| Analog outputs | 1: Configurable as voltage (0…10 V) or current (0-20 mA) | ||
| Digital outputs | 1: Configurable as sink or source | ||
| Relay outputs | 2: 1 with NO/NC contacts and 1 with NO contacts | ||
| Safety function inputs | 1 + 4: 1 with STO and 4 configurable for Safety functions from digital inputs |