| Typus vocabulorum | TF1 - _ _ -001- 6 _ - 106 CANopen (praesto 2nd quarter MMXIX) | ||
| Data electrica | |||
| metiri variables | Positio, celeritas et temperatus | ||
| Electrical metiendi range (dimensio B) | C ad 1000 | mm | |
| Celeritas range mensuræ | 0 ... 10 | ms-1 | |
| Output signum / protocol | Protocollum CANopen ad CiA DS-301 V4.2.0; Fabrica profile DS-406 V3.2 Encoder classis 1, LSS officia ad CiA DS-305 V1.1.2 |
||
| Programmabilis parametri | Cams, opus areas, nodi-ID, baud rate | ||
| Nodus-ID | 1 … 127 (default 127) | ||
| Baud rate | 20 … 1000 | kBaud | |
| Update rate (output) | 1 | kHz | |
| , | 1 5 0.1 0.5 |
µm mms-1 | |
| Dimensio B < 400 mm Dimensio B > 400 mm |
Princeps prec modus < 5 < 8 |
libratum modus < 10 < 15 |
µm µm |
| Signum propagationis mora | < 3 | < 1 ms | |
| Hysteresis | < 5 < 10 µm | ||
| Absoluta linearity | < 100 ± µm | ||
| Patientia electr. nullus punctus | 1 | ± mm | |
| Temperatus error | < 15 (min. 0.01 mm/K) | ppm/K | |
| Supple voltage | 24 (18 … 32) | VDC | |
| Supple voltage laniatus | < 10 | % Vss | |
| Virtus exhaurire (w / o onus) | 2.4 | W | |
| Overvoltage praesidium | 36 (per- petuum); | VDC | |
| Veritatem praesidio | Ita, usque ad max intentionem supplendam. | ||
| Brevis circuitus praesidium | Ita (vs. GND outputs et voltage max subauditur). | ||
| Nulla resistentia (500 VDC) | > 10 | MΩ | |
| Internus bus terminationem | non (Ous internum in petitione resistentia CXX Ω) | ||
| Environmental Data | |||
| MTF (DIN EN ISO 13849-1 partes computant modum, w/o onus, we) |
> 20 | Annos | |
| Novotechnik TF1 Transducer | TF1-0800-001-611-106 | Digital Versiones | |
| Novotechnik TF1 Transducer | TF1-0800-001-632-106 | Digital Versiones | |
| Novotechnik TF1 Transducer | TF1-0800-001-613-106 | Digital Versiones | |
| Novotechnik TF1 Transducer | TF1-0800-001-634-106 | Digital Versiones | |
| Novotechnik TF1 Transducer | TF1-0800-001-615-106 | Digital Versiones | |
| Novotechnik TF1 Transducer | TF1-0800-001-637-106 | Digital Versiones | |
| Novotechnik TF1 Transducer | TF1-0800-001-618-106 | Digital Versiones | |
| Novotechnik TF1 Transducer | TF1-0800-001-639-106 | Digital Versiones |