Availability: | |
---|---|
Novotechnik NOVOPAD Transducer up to 1000 mm touchless Series TF1
We can Supply all kinds of Novotechnik Transducer sensor parts,such as Novotechnik Linear Position Transducers,Novotechnik Rotary Sensor,Novotechnik Signal Conditioners and ect.
Type designations | TF1 – _ _ _ _ -001- 6 _ _ – 106 CANopen (available 2nd quarter 2019) | ||
Electrical Data | |||
Measured variables | Position, speed and temperature | ||
Electrical measuring range (dimension B) | 0100 up to 1000 | mm | |
Measuring range speed | 0 … 10 | ms-1 | |
Output signal / protocol | CANopen protocol to CiA DS-301 V4.2.0, Device profile DS-406 V3.2 Encoder class 1, LSS services to CiA DS-305 V1.1.2 | ||
Programmable parameter | Cams, working areas, node-ID, baud rate | ||
Node-ID | 1 … 127 (default 127) | ||
Baud rate | 20 … 1000 | kBaud | |
Update rate (output) | 1 | kHz | |
Resolution Position Resolution Speed | 1 5 0.1 0.5 | µm mms-1 | |
Reproducibility (rounded to resolution) Dimension B < 400 mm Dimension B > 400 mm | High prec mode < 5 < 8 | Balanced mode < 10 < 15 | µm µm |
Signal propagation delay | < 3 | < 1 ms | |
Hysteresis | < 5 < 10 µm | ||
Absolute linearity | < 100 ± µm | ||
Tolerance of electr. zero point | 1 | ± mm | |
Temperature error | < 15 (min. 0.01 mm/K) | ppm/K | |
Supply voltage | 24 (18 … 32) | VDC | |
Supply voltage ripple | < 10 | % Vss | |
Power drain (w/o load) | 2.4 | W | |
Overvoltage protection | 36 (permanent) | VDC | |
Polarity protection | Yes, up to supply voltage max. | ||
Short circuit protection | Yes (outputs vs. GND and supply voltage max.) | ||
Insulation resistance (500 VDC) | > 10 | MΩ | |
Bus termination internal | no (internal load resistance 120 Ω on request) | ||
Environmental Data | |||
MTTF (DIN EN ISO 13849-1 parts count method, w/o load, wc) | > 20 | Years | |
Novotechnik TF1 Transducer | TF1-0800-001-611-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-632-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-613-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-634-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-615-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-637-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-618-106 | Digital Versions | |
Novotechnik TF1 Transducer | TF1-0800-001-639-106 | Digital Versions |