Availability: | |
---|---|
Panasonic Proximity Sensor GX-F6A(I) GX-F6B(I) GX-F6A(I)-P GX-F6B(I)-P
Panasonic Rectangular-shaped Inductive Proximity Sensor GX-F/H
We can Supply all kinds of Panasonic sensor parts,such as Panasonic Micro Photoelectric Sensors,Panasonic Area Sensor,Panasonic Digital Fiber Sensor,Panasonic Fiber Sensor,Panasonic Laser Sensor,Panasonic Photoelectric Sensor,Panasonic Pressure Sensors and Panasonic Proximity Sensor.
Type | NPN output | PNP output | ||
Front sensing | GX-F6A(I) | GX-F6B(I) | GX-F6A(I)-P | GX-F6B(I)-P |
Top sensing | GX-H6A(I) | GX-H6B(I) | GX-H6A(I)-P | GX-H6B(I)-P |
CE marking directive compliance | EMC Directive, RoHS Directive | |||
Max. operation distance (Note 3) | 1.6 mm 0.063 in ± 8 % | |||
Stable sensing range (Note 3) | 0 to 1.3 mm 0 to 0.051 in | |||
Standard sensing object | Iron sheet 12 x 12 x t 1 mm 0.472 x 0.472 x t 0.039 in | |||
Hysteresis | 20 % or less of operation distance (with standard sensing object) | |||
Repeatability | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less | |||
Supply voltage | 12 to 24 V DC+10/-15% Ripple P-P 10 % or less | |||
Current consumption | 15 mA or less | |||
Output | NPN open-collector transistor – Maximum sink current: 100 mA – Applied voltage: 30 V DC or less (between output and 0 V) – Residual voltage: 2 V or less (at 100 mA sink current) | PNP open-collector transistor – Maximum source current: 100 mA – Applied voltage: 30 V DC or less(between output and +V) – Residual voltage: 2 V or less (at 100 mA source current) | ||
Utilization | DC-12 or DC-13 | |||
Output operation | Normally open | Normally closed | Normally open | Normally closed |
Max. response frequency | 400 Hz | |||
Operation indicator | Orange LED (lights up when the output is ON) | |||
Pollution degree | 3 (Industrial environment) | |||
Protection | IP68 (IEC), IP68G (Note 4, 5) | |||
Ambient temperature | -25 to +70 ℃ -13 to +158 ℉, Storage: -40 to +85 ℃ -40 to +185 ℉ | |||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 95 % RH | |||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | |||
Insulation resistance | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | |||
Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each | |||
Shock resistance | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each | |||
Temperature | Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within ±8 % of sensing range at +23℃ +73 ℉. | |||
Voltage characteristics | Within ±2 % for +10/-15 % fluctuation of the supply voltage | |||
Material | Enclosure: PBT, Indicator part: Polyester | |||
Cable | 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long | |||
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | |||
Net weight | 15 g approx. |