Panasonic Digital Pressure Sensor(For Gas) DP-001 DP-001-P DP-002 DP-002-P
We can Supply all kinds of Panasonic sensor parts,such as Panasonic Micro Photoelectric Sensors,Panasonic Area Sensor,Panasonic Digital Fiber Sensor,Panasonic Fiber Sensor,Panasonic Laser Sensor,Panasonic Photoelectric Sensor,Panasonic Pressure Sensors and Panasonic Proximity Sensor.
Type | Low pressure | High pressure |
Model No.NPN output | DP-001 | DP-002 |
Model No.PNP output | DP-001-P | DP-002-P |
CE marking directive compliance | EMC Directive, RoHS Directive | |
Type of pressure | Gauge pressure | |
Rated pressure range | -100.0 to +100.0 kPa | 0.000 to +1.000 MPa |
Set pressure range | -101.0 to +101.0 kPa -1.030 to +1.030 kgf/cm2 -1.010 to + 1.010 bar -14.65 to +14.65 psi -756 to +756 mmHg | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi |
Pressure withstandability | 500 kPa | 1.5 MPa |
Applicable fluid | Air, non-corrosive gas | |
Selectable unit | Low pressure type: kPa, kgf/cm2, bar, psi, mmHg High pressure type: MPa, kgf/cm2, bar, psi | |
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | |
Power consumption | 30 mA or less | |
Comparative output | <NPN output type> NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between comparative output and 0 V) • Residual voltage: 2 V or less (at 50 mA sink current)<PNP output type> PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (between comparative output and +V) • Residual voltage: 2 V or less (at 50 mA source current) | |
Output operation | Selectable either NO or NC by key operation | |
Hysteresis | Minimum 2 digits (variable) | |
Repeatability | ±0.2 % F.S. (within ±4 digits) | ±0.4 % F.S. (within ±4 digits) |
Response time | 2.5 ms, 25 ms, 250 ms, selectable by key operation | |
Short-circuit protection | Incorporated | |
Display | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) | |
Protection | IP40 (IEC) | |
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |
Voltage withstandability | 500 V AC for one min. between all supply terminals connected together and enclosure | |
Insulation resistance | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure | |
Vibration resistance | 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each | |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | |
Pollution degree | 2 | |
Overvoltage category | I | |
Usable altitude | 2,000 m 6,562 ft or less | |
Temperature characteristics (+20℃ standard) | +10 to +40℃ +50 to +104 ℉: Within ±1 % F.S. 0 to +50℃ 32 to +122℉: Within ±2.5 % F.S. | +10 to +40℃ +50 to +104℉: Within ±2 % F.S. 0 to +50℃ 32 to +122℉: Within ±5 % F.S. |
Grounding method | Floating | |
Pressure port | M5 female thread | |
Material | Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Brass (nickel plated), Mounting threaded part: Brass, O-ring: Nitrile rubber (NBR), Key section: Polycarbonate | |
Weight | 25 g approx. | |
Accessory | CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1 pc. |