| Availability: | |
|---|---|
Siemens PLCs SIMATIC S7-1500 Module 6ES7521-1BH00-0AB0 6ES7521-1BH10-0AA0
Partes automationes Siemens supplere possumus, ut Siemens PLC, Siemens Servo Motor, Siemens HMI, Siemens VFD et sic porro;
| Articulus numerus | 6ES7521-1BH00-0AB0 | 6ES7521-1BL00-0AB0 | 6ES7521-1BH50-0AA0 | 6ES7521-1FH00-0AA0 | 6ES7521-7EH00-0AB0 |
| S7-1500, DI 16x24VDC HF | S7-1500, DI 32x24VDC HF | S7-1500, DI 16x24VDC SRC BA | S7-1500, DI 16x230VAC BA | S7-1500, DI 16 x 24…125V UC HF | |
| Generalis notitia | |||||
| Product genus designatio | DI 16x24VDC HF | DI 32x24VDC HF | DI 16x24VDC SRC BA | DI 16x230VAC BA | DI 16×24 ... 125 V UC HF |
| HW status eget | ex FS04 | ex FS04 | FS01 | FS01 | FS01 |
| Firmware version | V2.2.0 | V2.2.1 | V2.0.0 | V2.0.0 | V1.0.0 |
| FW update potest | Ita | Ita | Ita | Ita | Ita |
| Munus productum | |||||
| I&M data | Ita; I & M0 ad me & M3 | Ita; I & M0 ad me & M3 | Ita; I & M0 ad me & M3 | Ita; I & M0 ad me & M3 | Ita; I & M0 ad me & M3 |
| Isochronae modus | Ita | Ita | No | No | No |
| Prioritized startup | Ita | Ita | Ita | Ita | Ita |
| Ipsum cum | |||||
| VERSUS 7 TIA Portal configurable/integrata ex versione | V13 SP1 / - | V13 SP1 / - | V12/V12 | V12/V12 | V13 SP1 / - |
| PASSUS VII configurable / integrated ex versione | V5.5 SP3 / - | V5.5 SP3 / - | V5.5 SP3 / - | V5.5 SP3 / - | V5.5 SP3 / - |
| ● PROFIBUS ex GSD versionis / GSD recognitione | V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 |
| PROFINET ex versione GSD / revision GSD | V2.3 / - | V2.3 / - | V2.3 / - | V2.3 / - | V2.3 / - |
| Modus operating | |||||
| DI | Ita | Ita | Ita | Ita | Ita |
| Counter | Ita | Ita | No | No | No |
| Oversampling | No | No | No | ||
| MSI | Ita | Ita | Ita | Ita | Ita |
| Supple voltage | |||||
| Ratum valorem (DC) | 24 V | 24 V | |||
| licet range, inferior terminus (DC) | 20.4 V | 20.4 V | 20.4 V | ||
| licet rhoncus evolvimus (DC) | 28.8 V | 28.8 V | 28.8 V | ||
| Reverse verticitatem praesidium | Ita | Ita | |||
| Input current | |||||
| Current consummatio max. | 20 mA; with 24 V DC | 40 mA; 20 mA per group cum 24 V DC supple | |||
| Potestas | |||||
| Potentia available a backplane bus | 1.1 W | 1.1 W | 0.9 W | 1 W | 1.2 W |
| Virtus damnum | |||||
| Virtutis amissio, typ. | 2.6 W | 4.2 W | 2.8 W | 4.9 W | 2.2 W; dc tempore 24 v; 6.0 W at 125 V AC |
| Digital inputs | |||||
| Numerus inputs digitales | 16 | 32 | 16 | 16 | 16 |
| Digital inputs, parameterizable | Ita | Ita | No | No | Ita |
| Source/input descendat | P-lection | P-lection | Sourcing | P-lection | Ita |
| Input lineae characteristicae ad normam IEC 61131, typus 1 | Ita | ||||
| Input lineae characteristicae ad normam IEC 61131, typus 3 | Ita | Ita | Ita | Ita; Ad 24 V DC | |
| Input functiones digitales, parameterizable | |||||
| Porta satus/statur | Ita | Ita | |||
| ● Gratis utibile digital input | Ita | Ita | |||
| Counter | |||||
| — Numero max. | 2 | 2 | |||
| — Numerandi frequentiam max. | 3 kHz | 3 kHz; FS04 and FW V2.2.1 or higher | |||
| - latitudinem | 32 bit | 32 bit | |||
| - Counting directionem sursum / in | Up | Up | |||
| Input voltage | |||||
| Ratum valorem (DC) | 24 V | 24 V | 24 V | 24 v; 48 V, 125 V | |
| — 24 V DC | Ita | Ita | Ita | Ita | |
| Ratum valorem (AC) | 230 V; 120/230 V AC, 50/60 Hz | 24 v; 48 V, 125 V (50 – 60 Hz); | |||
| pro signo '0' | -30 ad +5 V | -30 ad +5 V | -5 ad +30V | 0V AC ad 40V AC | -5 ... +5 V |
| pro signo '1' | +11 ad +30V | +11 ad +30V | -11 ad -30V | 79V AC ad 264V AC | +11 ... +146 V |
| Input current | |||||
| pro signo '1', typ. | 2.5 mA | 2.5 mA | 4.5 mA | 11 mA; Ad 230 V AC et 5.5 mA ad 120 V AC | 3 mA; Ad 24 V DC |
| Input mora (pro aestimavit valorem input voltage) | |||||
| quia vexillum initibus | |||||
| - parameterizable | Ita; 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms | Ita; 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms | No | No | Ita; 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms parameterizabile cum DC, 20 ms cum AC fixum. |
| — ad '0' ad '1', min. | 0.05 ms | 0.05 ms | 3 ms | 0.05 ms | |
| — ad '0' ad '1', max. | 20 ms | 20 ms | 4 ms | 25 ms | 20 ms |
| — ad '1' ad '0', min. | 0.05 ms | 0.05 ms | 3 ms | 0.05 ms | |
| — ad '1' ad '0', max. | 20 ms | 20 ms | 4 ms | 25 ms | 20 ms |
| ad interpellandum initibus | |||||
| - parameterizable | Ita | Ita | No | No | Ita |
| ad technologicum munera | |||||
| - parameterizable | Ita | Ita | No | No | No |
| Cable longitudo | |||||
| tuta max. | 1 000 m | 1 000 m | 1 000 m | 1 000 m | 1 000 m |
| obtentu max. | DC m | DC m | DC m | DC m | DC m |
| Encoder | |||||
| Encoders Connectable | |||||
| 2-filum sensorem | Ita | Ita | Ita | Ita | Ita |
| — licitum quiescit vena (2-filum sensorem), max. | 1.5 mA | 1.5 mA | 1.5 mA | 2 mA | 1.5 mA |
| Isochronae modus | |||||
| Percolando et dispensando tempore (TCI), min. | 80 µs; In 50 μs filter in tempore | 80 µs; In 50 μs filter in tempore | |||
| Bus cycli temporis (TDP), min. | 250 µs | 250 µs | |||
| Obloquitur / diagnostica / status informationes | |||||
| Functio diagnostica | Ita | Ita | No | No | Ita |
| Alanus | |||||
| Diagnostic terror | Ita | Ita | No | No | Ita |
| Hardware interpellare | Ita | Ita | No | No | Ita |
| Diagnoses | |||||
| Cras copia voltage | Ita | Ita | No | No | No |
| Wire-confractus | Ita; ad I < 350 µA | Ita; ad I < 350 µA | No | No | Ita; Ad I < 550 µA |
| Brevis circuitus | No | No | No | No | No |
| Diagnostics significatio LED | |||||
| CURSUS LED | Ita; viridi LED | Ita; viridi LED | Ita; viridi LED | Ita; viridi LED | Ita; viridi LED |
| ERROR LED | Ita; red LED | Ita; red LED | Ita; red LED | Ita; red LED | Ita; red LED |
| Cras copiae intentione (PWR-LED) | Ita; viridi LED | Ita; viridi LED | No | No | No |
| Channel status ostentationem | Ita; viridi LED | Ita; viridi LED | Ita; viridi LED | Ita; viridi LED | Ita; viridi LED |
| ad channel diagnostica | Ita; red LED | Ita; red LED | No | No | Ita; red LED |
| ad moduli diagnostica | Ita; red LED | Ita; red LED | No | Ita; red LED | Ita; red LED |
| Potentia separationis | |||||
| Canales separationis potentiale | |||||
| inter canales | No | Ita | No | No | Ita |
| inter canales, in coetibus | 16 | 16 | 16 | 4 | 1 |
| inter canales et backplane bus | Ita | Ita | Ita | Ita | Ita |
| inter vias et copiam electronicorum potentiae | No | No | |||
| Licet differentia potentiale | |||||
| inter diversas circulos | 250 V AC inter canales et backplani bus; D V AC inter canales | 146 V DC/132 V AC | |||
| Separatio | |||||
| Solitudo probata est | 707 V DC (genus test) | 707 V DC (genus test) | 707 V DC (genus test) | 3 100 V DC | 2 000 V DC |
| Signa, approbationes, testimoniales | |||||
| Apta munera ad salutem | No | No | No | No | No |
| condiciones ambientes | |||||
| Ambiens temperatus per operationem | |||||
| institutionem horizontalem, min. | -30 °C; Ex FS05 | -30 °C; Ex FS05 | 0 °C | 0 °C | 0 °C |
| institutionem horizontalem, max. | 60 °C | 60 °C | 60 °C | 60 °C | 60 °C |
| vertical institutionem, min. | -30 °C; Ex FS05 | -30 °C; Ex FS05 | 0 °C | 0 °C | 0 °C |
| vertical institutionem, max. | 40 °C | 40 °C | 40 °C | 40 °C | 40 °C |
| Altitudo in operatione quae est ad mare campester | |||||
| ● Altitudo instruitur supra mare planum, max. | 5 000 m; Restrictiones ad institutionem altitudinum > 2 000 m, vide manuale | 5 000 m; Restrictiones ad institutionem altitudinum > 2 000 m, vide manuale | 5 000 m; Restrictiones ad institutionem altitudinum > 2 000 m, vide manuale | ||
| Dimensiones | |||||
| Latitudo | 35 mm | 35 mm | 35 mm | 35 mm | 35 mm |
| Altitudo | 147 mm | 147 mm | 147 mm | 147 mm | 147 mm |
| Profundum | 129 mm | 129 mm | 129 mm | 129 mm | 129 mm |
| Ponderibus | |||||
| Pondus, approx. | 240 g | 260 g | 230 g | 300 g | 240 g |