| Mavjudligi: | |
|---|---|
Siemens PLCs SM532 analog chiqish modullari 6ES7532-5HD00-0AB0 6ES7532-5HF00-0AB0
Biz Siemens PLC, Siemens Servo Motor, Siemens HMI, Siemens VFD va boshqalar kabi Siemens avtomatlashtirish qismlarini etkazib bera olamiz,
| modda raqami | 6ES7532-5NB00-0AB0 | 6ES7532-5HD00-0AB0 | 6ES7532-5HF00-0AB0 | 6ES7532-5ND00-0AB0 |
| S7-1500, AQ 2xU/I ST | S7-1500, AQ 4xU/I ST | S7-1500, AQ 8xU/I HS | S7-1500, AQ 4xU/I HF | |
| Umumiy ma'lumot | ||||
| Mahsulot turini belgilash | AQ 2xU/I ST | AQ 4xU/I ST | AQ 8xU/I HS | AQ 4xU/I HF |
| HW funktsional holati | FS01 | FS04 dan | FS01 dan | FS01 dan |
| Mikrodastur versiyasi | V1.0.0 | V2.2.0 | V2.1.0 | V1.1.0 |
| ● FW yangilanishi mumkin
|
Ha | Ha | Ha | Ha |
| Mahsulot funktsiyasi | ||||
| ● I&M maʼlumotlari
|
Ha; I&M0 - I&M3 | Ha; I&M0 - I&M3 | Ha; I&M0 - I&M3 | Ha; I&M0 - I&M3 |
| ● Isoxron rejimi
|
Yo'q | Yo'q | Ha | Ha |
| ● ustuvor ishga tushirish
|
Yo'q | Yo'q | Yo'q | Ha |
| ● Chiqish diapazoni kengaytirilishi mumkin
|
Yo'q | Yo'q | Yo'q | |
| Bilan muhandislik | ||||
| ● STEP 7 TIA Portal versiyasidan sozlanishi/integratsiyalangan
|
V13 / V13.0.2 | V12 / V12 | V14 / - | V14 / - |
| ● STEP 7 versiyasidan sozlanishi/integratsiyalangan
|
V5.5 SP3 / - | V5.5 SP3 / - | V5.5 SP3 / - | V5.5 SP3 / - |
| ● GSD versiyasi/GSD reviziyasidan PROFIBUS
|
V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 |
| ● GSD versiyasi/GSD reviziyasidan PROFINET
|
V2.3 / - | V2.3 / - | V2.3 / - | V2.3 / - |
| Ishlash rejimi | ||||
| ● Haddan tashqari namuna olish
|
Yo'q | Yo'q | Ha | Yo'q |
| ● MSO
|
Ha | Ha | Ha | Ha |
| CiR - RUN da konfiguratsiya | ||||
| RUN da qayta parametrlash mumkin | Ha | Ha | Ha | Ha |
| RUN da kalibrlash mumkin | Ha | Ha | Ha | Ha |
| Ta'minot kuchlanishi | ||||
| Ta'minot kuchlanishining turi | DC | DC | DC | DC |
| Nominal qiymat (DC) | 24 V | 24 V | 24 V | 24 V |
| ruxsat etilgan diapazon, pastki chegara (DC) | 20,4 V | 20,4 V | 20,4 V | 20,4 V |
| ruxsat etilgan diapazon, yuqori chegara (DC) | 28,8 V | 28,8 V | 28,8 V | 28,8 V |
| Teskari polaritdan himoya qilish | Ha | Ha | Ha | Ha |
| Kirish oqimi | ||||
| Joriy iste'mol, maks. | 110 mA; 24 V doimiy kuchlanish bilan | 190 mA; 24 V doimiy kuchlanish bilan | 260 mA; 24 V doimiy kuchlanish bilan | 160 mA; 24 V doimiy kuchlanish bilan |
| Quvvat | ||||
| Orqa panel avtobusidan quvvat olish mumkin | 0,65 Vt | 0,6 Vt | 1,15 Vt | 0,95 Vt |
| Quvvat yo'qolishi | ||||
| Quvvatni yo'qotish, tip. | 2,7 Vt | 4 Vt | 7 Vt | 5 Vt |
| Analog chiqishlar | ||||
| Analog chiqishlar soni | 2 | 4 | 8 | 4 |
| Chiqish kuchlanishi, qisqa tutashuvdan himoya qilish | Ha | Ha | Ha | Ha |
| Chiqish kuchlanishi, qisqa tutashuv oqimi, maks. | 24 mA | 24 mA | 45 mA | 24 mA |
| Oqim chiqishi, yuksiz kuchlanish, maks. | 22 V | 22 V | 20 V | 22 V |
| Tsikl vaqti (barcha kanallar), min. | 3,2 ms; faollashtirilgan kanallar sonidan qat'iy nazar | 3,2 ms; faollashtirilgan kanallar sonidan qat'iy nazar | 125 mks; faollashtirilgan kanallar sonidan qat'iy nazar | 125 mks; faollashtirilgan kanallar sonidan qat'iy nazar |
| Chiqish diapazonlari, kuchlanish | ||||
| ● 0 dan 10 V gacha
|
Ha | Ha | Ha | Ha |
| ● 1 V dan 5 V gacha
|
Ha | Ha | Ha | Ha |
| ● -5 V dan +5 V gacha
|
Yo'q | Yo'q | Yo'q | Yo'q |
| ● -10 V dan +10 V gacha
|
Ha | Ha | Ha | Ha |
| Chiqish diapazonlari, oqim | ||||
| ● 0 dan 20 mA gacha
|
Ha | Ha | Ha | Ha |
| ● -20 mA dan +20 mA gacha
|
Ha | Ha | Ha | Ha |
| ● 4 mA dan 20 mA gacha
|
Ha | Ha | Ha | Ha |
| Aktuatorlarning ulanishi | ||||
| ● kuchlanish chiqishi ikki simli ulanish uchun
|
Ha | Ha | Ha | Ha |
| ● kuchlanishli chiqish to'rt simli ulanish uchun
|
Ha | Ha | Ha | Ha |
| ● joriy chiqish ikki simli ulanish uchun
|
Ha | Ha | Ha | Ha |
| Yuk empedansi (nominal chiqish oralig'ida) | ||||
| ● kuchlanish chiqishlari bilan, min.
|
1 kŌ; 0,5 kOm 1 dan 5 V gacha | 1 kŌ; 0,5 kOm 1 dan 5 V gacha | 1 kŌ | 1 kŌ; 0,5 kOm 1 dan 5 V gacha |
| ● kuchlanish chiqishlari bilan, sig'imli yuk, maks.
|
1 mkF | 1 mkF | 100 nF | 1 mkF |
| ● oqim chiqishlari bilan, maks.
|
750 Ō | 750 Ō | 500 Ō | 750 Ō |
| ● oqim chiqishlari bilan, induktiv yuk, maks.
|
10 mH | 10 mH | 1 mH | 10 mH |
| Kabel uzunligi | ||||
| ● ekranlangan, maks.
|
800 m; oqim uchun, kuchlanish uchun 200 m | 800 m; oqim uchun, kuchlanish uchun 200 m | 200 m | 800 m; oqim uchun, kuchlanish uchun 200 m |
| Chiqishlar uchun analog qiymat yaratish | ||||
| Har bir kanal uchun integratsiya va konvertatsiya vaqti/ravshanligi | ||||
| ● Haddan tashqari diapazonli ruxsat (bit, shu jumladan belgisi), maks.
|
16 bit | 16 bit | 16 bit | 16 bit |
| ● Konversiya vaqti (har bir kanal uchun)
|
0,5 ms | 0,5 ms | 50 mks; faollashtirilgan kanallar sonidan qat'iy nazar | 125 mks; faollashtirilgan kanallar sonidan qat'iy nazar |
| O'rnatish vaqti | ||||
| ● rezistiv yuk uchun
|
1,5 ms | 1,5 ms | 30 mks; qo'llanmadagi qo'shimcha tavsifga qarang | 0,2 ms; qo'llanmadagi qo'shimcha tavsifga qarang |
| ● sig'imli yuk uchun
|
2,5 ms | 2,5 ms | 100 mks; qo'llanmadagi qo'shimcha tavsifga qarang | 1,8 ms; qo'llanmadagi qo'shimcha tavsifga qarang |
| ● induktiv yuk uchun
|
2,5 ms | 2,5 ms | 100 mks; qo'llanmadagi qo'shimcha tavsifga qarang | 2 ms; qo'llanmadagi qo'shimcha tavsifga qarang |