Availability: | |
---|---|
Keyence Fiber Optic Sensors FS-N40
We can Supply all kinds of Keyence sensor parts,such as Keyence Digital Laser Sensors,Keyence Vision Sensors,Keyence Fiber Optic Sensors,Keyence Inductive Proximity Sensors,Keyence Photoelectric Sensors,Keyence Positioning Sensors and So on.
Model | FS-N40 |
Type | Zero Line Type |
Main unit/expansion unit | Expansion unit |
Number of control outputs | None*1 |
Light source LED | Transmitter side: Red, four-element LED (wavelength: 660 nm) |
Response time | 23 µs (S-HSPD*2) /50 µs (HSPD*3) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) |
External input | Input time: 2 ms (ON) /20 ms (OFF) or longer*4 |
Unit expansion | Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units. |
Protection circuit | Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
Mutual interference prevention | S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.) |
Power supply Power voltage | 10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*5 |
Power consumption | During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V) ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V) ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)*6 |
Environmental resistance Ambient light | Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less |
Ambient temperature | -20 °C -4 °F to +55 °C +131 °F (no freezing)*7 |
Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm 0.06″; 2 hours each for X, Y, and Z axes |
Shock resistance | 500 m/s2; 3 times each for X, Y, and Z axes |
Case material | Main unit and cover: polycarbonate |
Weight | Approx. 23 g |