Availability: | |
---|---|
Product Details
Siemens PLCs SIMATIC S7-1500 Module 6ES7522-1BP00-0AA0 6ES7522-1BP50-0AA0
We are First Class Siemens Supplier,siemens plc dealer and Siemens plc distributor in China.
We can Supply Siemens automation parts,such as Siemens PLC,Siemens Servo Motor,Siemens HMI,Siemens VFD and So on,
100% Original and new,In stock by Siemens Automation
Delivery time: Ready in stock and 1 days for ship out
MOQ: 1pcs
Specification
Article number | 6ES7522-1BH10-0AA0 | 6ES7522-1BL10-0AA0 |
S7-1500, DQ 16x24VDC/0.5A BA | S7-1500, DQ 32x24VDC/0.5A BA | |
General information | ||
Product type designation | DQ 16x24VDC/0.5A BA | DQ 32x24VDC/0.5A BA |
HW functional status | FS01 | FS01 |
Firmware version | V1.0.0 | V1.0.0 |
● FW update possible | Yes | Yes |
Product function | ||
● I&M data | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 |
● Isochronous mode | No | No |
● Prioritized startup | Yes | Yes |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated from version | V13 / V13 | V13 / V13 |
● STEP 7 configurable/integrated from version | V5.5 SP3 / – | V5.5 SP3 / – |
● PROFIBUS from GSD version/GSD revision | V1.0 / V5.1 | V1.0 / V5.1 |
● PROFINET from GSD version/GSD revision | V2.3 / – | V2.3 / – |
Operating mode | ||
● DQ | Yes | Yes |
● DQ with energy-saving function | No | No |
● PWM | No | No |
● Oversampling | No | No |
● MSO | Yes | Yes |
Supply voltage | ||
Rated value (DC) | 24 V | 24 V |
permissible range, lower limit (DC) | 20.4 V | 20.4 V |
permissible range, upper limit (DC) | 28.8 V | 28.8 V |
Reverse polarity protection | Yes; through internal protection with 7 A per group | Yes; through internal protection with 7 A per group |
Input current | ||
Current consumption, max. | 30 mA | 60 mA |
Output voltage | ||
Rated value (DC) | 24 V | 24 V |
Power | ||
Power available from the backplane bus | 1.15 W | 1.15 W |
Power loss | ||
Power loss, typ. | 2.2 W | 3.8 W |
Digital outputs | ||
Type of digital output | Transistor | Transistor |
Number of digital outputs | 16 | 32 |
Current-sourcing | Yes | Yes |
Digital outputs, parameterizable | No | No |
Short-circuit protection | Yes | Yes |
● Response threshold, typ. | 1 A | 1 A |
Limitation of inductive shutdown voltage to | L+ (-53 V) | L+ (-53 V) |
Controlling a digital input | Yes | Yes |
Switching capacity of the outputs | ||
● with resistive load, max. | 0.5 A | 0.5 A |
● on lamp load, max. | 5 W | 5 W |
Load resistance range | ||
● lower limit | 48 Ω | 48 Ω |
● upper limit | 12 kΩ | 12 kΩ |
Output voltage | ||
● for signal “1”, min. | L+ (-0.8 V) | L+ (-0.8 V) |
Output current | ||
● for signal “1” rated value | 0.5 A | 0.5 A |
● for signal “1” permissible range, max. | 0.5 A | 0.5 A |
● for signal “0” residual current, max. | 0.5 mA | 0.5 mA |
Output delay with resistive load | ||
● “0” to “1”, max. | 100 µs | 100 µs |
● “1” to “0”, max. | 500 µs | 500 µs |
Parallel switching of two outputs | ||
● for logic links | Yes | Yes |
● for uprating | No | No |
● for redundant control of a load | Yes | Yes |
Switching frequency | ||
● with resistive load, max. | 100 Hz | 100 Hz |
● with inductive load, max. | 0.5 Hz; According to IEC 60947-5-1, DC-13 | 0.5 Hz; According to IEC 60947-5-1, DC-13 |
● on lamp load, max. | 10 Hz | 10 Hz |
Total current of the outputs | ||
● Current per channel, max. | 0.5 A; see additional description in the manual | 0.5 A; see additional description in the manual |
● Current per group, max. | 4 A; see additional description in the manual | 4 A; see additional description in the manual |
● Current per module, max. | 8 A; see additional description in the manual | 16 A; see additional description in the manual |
Cable length | ||
● shielded, max. | 1 000 m | 1 000 m |
● unshielded, max. | 600 m | 600 m |
Interrupts/diagnostics/status information | ||
Diagnostics function | No | No |
Substitute values connectable | No | No |
Alarms | ||
● Diagnostic alarm | No | No |
● Maintenance interrupt | No | No |
Diagnoses | ||
● Monitoring the supply voltage | No | No |
● Wire-break | No | No |
● Short-circuit | No | No |
● Group error | No | No |
Diagnostics indication LED | ||
● RUN LED | Yes; green LED | Yes; green LED |
● ERROR LED | Yes; red LED | Yes; red LED |
● Monitoring of the supply voltage (PWR-LED) | Yes; green LED | Yes; green LED |
● Channel status display | Yes; green LED | Yes; green LED |
● for channel diagnostics | No | No |
● for module diagnostics | No | No |
Potential separation | ||
Potential separation channels | ||
● between the channels | No | No |
● between the channels, in groups of | 8 | 8 |
● between the channels and backplane bus | Yes | Yes |
Isolation | ||
Isolation tested with | 707 V DC (type test) | 707 V DC (type test) |
Standards, approvals, certificates | ||
Suitable for safety functions | No | No |
Altitude during operation relating to sea level | ||
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
Dimensions | ||
Width | 25 mm | 25 mm |
Height | 147 mm | 147 mm |
Depth | 129 mm | 129 mm |
Weights | ||
Weight, approx. | 230 g | 280 g |