Availability: | |
---|---|
Omron Proximity Sensor E2E-X2D1-N/-X2D2-N/-X3D1-N E2E-X3D2-N/-X7D1-N/-X7D2-N
Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E
We can Supply all kinds of Omron sensor parts,such as Omron Photomicro Sensors,Omron Proximity Sensors,Omron Fiber Sensors,Omron Photoelectric Sensors and Omron Rotary Encoder.
Size | M8 | M12 | M18 | M30 | ||||
Shielded | Shielded | Unshielded | Shielded | Unshielded | Shielded | Unshielded | Shielded | Unshielded |
Item Model | E2E-X2D@ | E2E-X4MD@ | E2E-X3D@ | E2E-X8MD@ | E2E-X7D@ | E2E-X14MD@ | E2E-X10D@ | E2E-X20MD@ |
Sensing distance | 2 mm ±10% | 4 mm ±10% | 3 mm ±10% | 8 mm ±10% | 7 mm ±10% | 14 mm ±10% | 10 mm ±10% | 20 mm ±10% |
Set distance *1 | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 2.4 mm | 0 to 6.4 mm | 0 to 5.6 mm | 0 to 11.2 mm | 0 to 8 mm | 0 to 16 mm |
Differential travel | 15% max. of sensing distance | 10% max. of sensing distance | ||||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 17 and 18. | |||||||
Standard sensing object | Iron,8 ´ 8 ´ 1 mm | Iron,20 ´ 20 ´ 1 mm | Iron,12 ´ 12 ´ 1 mm | Iron,30 ´ 30 ´ 1 mm | Iron,18 ´ 18 ´ 1 mm | Iron, 30 ´ 30 ´ 1 mm | Iron,54 ´ 54 ´ 1 mm | |
Response frequency*2 | 1.5 kHz | 1 kHz | 0.8 kHz | 0.5 kHz | 0.4 kHz | 0.1 kHz | ||
Power supply voltage (operating voltage range) | Standard Models: 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC) US Models and Connector Models Used as UL-certified Models:12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3 | |||||||
Leakage current | 0.8 mA max. | |||||||
Load current | 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models | |||||||
Residual voltage | 3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.) | |||||||
Indicators | D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red) | |||||||
Operation mode (with sensing object approaching) | D1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 20 for details. D2 Models: NC | |||||||
Diagnostic output delay | 0.3 to 1 s | |||||||
Protection circuits | Surge suppressor, Load short-circuit protection (for control and diagnostic output) | |||||||
Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | |||||||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | |||||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||||||
Dielectric strength | 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case | |||||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||||
Shock resistance | Destruction: 500 m/s210 times each in X, Y, and Z directions | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 | |||||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m) |