Siemens PLCs CM 8xIO-Link Communication module 6ES7547-1JF00-0AB0
We are First Class Siemens Supplier,siemens plc dealer and Siemens plc distributor in China.
We can Supply Siemens automation parts,such as Siemens PLC,Siemens Servo Motor,Siemens HMI,Siemens VFD and So on,
100% Original and new,In stock by Siemens Automation
Delivery time: Ready in stock and 1 days for ship out
MOQ: 1pcs
Specification
Article number | 6ES7547-1JF00-0AB0 |
S7-1500, CM 8xIO-Link | |
General information | |
Product type designation | CM 8xIO-Link |
HW functional status | FS01 |
Firmware version | V1.0.0 |
● FW update possible | Yes |
Product function | |
● I&M data | Yes; I&M0 to I&M3 |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | V15.1 with HSP 274 |
● STEP 7 configurable/integrated from version | Configurable via GSD file |
● PROFIBUS from GSD version/GSD revision | GSD as of Revision 5 |
● PROFINET from GSD version/GSD revision | GSDML V2.34 |
Supply voltage | |
Type of supply voltage | 24 V DC |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Input current | |
Current consumption, max. | 50 mA; without load |
Encoder supply | |
Number of outputs | 8 |
Output current | |
● Rated value | 1 A; 4 A total current per module |
24 V encoder supply | |
● Short-circuit protection | Yes; per channel, electronic |
IO-Link | |
Number of ports | 8 |
● of which simultaneously controllable | 8 |
IO-Link protocol 1.0 | Yes |
IO-Link protocol 1.1 | Yes |
Cycle time, min. | 2 ms |
Size of process data, input per port | 33 byte; max. |
Size of process data, input per module | 240 byte; max. |
Size of process data, output per port | 32 byte; max. |
Size of process data, output per module | 240 byte; max. |
Memory size for device parameter | 2 kbyte; for each port |
Master backup | Yes |
Configuration without S7-PCT | Yes |
Cable length unshielded, max. | 20 m |
Operating modes | |
● IO-Link | Yes |
● DI | Yes |
● DQ | No |
Time Based IO | |
— TIO IO-Link IN | No |
— TIO IO-Link OUT | No |
— TIO IO-Link IN/OUT | No |
Connection of IO-Link devices | |
● Port type A | Yes |
● Port type B | Yes; 24 V DC via external terminal |
Interrupts/diagnostics/status information | |
Alarms | |
● Diagnostic alarm | Yes; The port diagnosis is available in the IO-Link mode only. |
Diagnoses | |
● Monitoring the supply voltage | Yes |
● Wire-break | Yes |
● Short-circuit | Yes |
● Group error | Yes |
Diagnostics indication LED | |
● Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
● Channel status display | Yes; green LED |
● for channel diagnostics | Yes; red LED |
● for module diagnostics | Yes; red LED |
Potential separation | |
Potential separation channels | |
● between the channels | No |
● between the channels and backplane bus | Yes |
Isolation | |
Isolation tested with | 707 V DC (type test) |
Ambient conditions | |
Ambient temperature during operation | |
● horizontal installation, min. | 0 °C |
● horizontal installation, max. | 60 °C; Observe derating |
● vertical installation, min. | 0 °C |
● vertical installation, max. | 40 °C; Observe derating |
Altitude during operation relating to sea level | |
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |