Availability: | |
---|---|
Novotechnik NOVOPAD Position Transducers Series LS1 with analog interface
We can Supply all kinds of Novotechnik Transducer sensor parts,such as Novotechnik Linear Position Transducers,Novotechnik Rotary Sensor,Novotechnik Signal Conditioners and ect.
Type designations | LS1 0025 | LS1 0050 | LS1 0075 | LS1 0100 | LS1 0150 | LS1 0200 | |
Electrical measuring range | 25 | 50 | 75 | 100 | 150 | 200 | mm |
Absolute linearity | < ± 0.1 | < ± 0.15 | % F.S. | ||||
Tolerance of electr. zero point | ± 0.5 | mm | |||||
Output signal voltage or current | 0.1…10 VDC (by load 470 kΩ) allowed load > 10 kΩ 10. 0.1 VDC (by load 470 kΩ) allowed load > 10 kΩ 4. 20 mA (burden < 500 Ω) 20. 4 mA (burden < 500 Ω) | ||||||
Internal resistance of voltage output | 120 | Ω | |||||
Output, short-circuit-proof | against supply max. 30 VDC and GND (permanent) | ||||||
Update Rate | high speed mode > 950; low speed mode > 50 | Hz | |||||
Repeatability | high speed mode < 10 mV, typical < 3 mV low speed mode < 5 mV, typical < 2 mV high speed mode < 16 µA, typical < 5 µA low speed mode < 8 µA, typical < 3 µA | mV mV µA µA | |||||
Supply voltage | 16…30 | VDC | |||||
Supply voltage ripple | max. 10 | % Vss | |||||
Power drain without load | < 1 | W | |||||
Temperature coefficient | < 50 | ppm/K | |||||
Overvoltage protection | < 40 (permanent) | VDC | |||||
Polarity protection | up to Umax | VDC | |||||
Insulation resistance (500 VDC) | > 10 | MΩ | |||||
Mechanical Data | |||||||
Body length (dimension A) | 63 | 88 | 113 | 138 | 188 | 238 | +1 mm |
Mechanical stroke (dimension B) | 30 | 55 | 80 | 105 | 155 | 205 | ±1,5 mm |
Weight approx. with cable | 140 | 160 | 170 | 190 | 220 | 260 | g |
with connector | 86 | 107 | 132 | 150 | 190 | 230 | g |
Operating force (horizontal) | ≤ 0.3 | N | |||||
Mobility of ball coupling | ± 1 mm parallel offset, ± 2.5° angular offset | ||||||
Maximum permitted tightening torque for fixing screws | 140 | Ncm | |||||
Environmental Data | |||||||
Operating temperature range | -40…+85 with connector -30…+100 with cable | °C °C | |||||
Operating humidity range | 0…95 (no condensation) | %RH | |||||
Shock per DIN IEC | 100 (11 ms) (single hit) | g | |||||
Vibration per DIN IEC | 20 (10…2000 Hz, Amax = 0.75 mm) | g | |||||
Protection class | IP 40 DIN EN 60529 | ||||||
Adjustment speed max. | 5 | m/s | |||||
Acceleration speed max. | 5 | g | |||||
Life | > 100×106 | movements | |||||
MTTF (ISO 13849-1, parts count method, w/o load) | 24 | years |