Availability: | |
---|---|
Panasonic Proximity Sensor GX-5SU/-8MU/-12MU/-18MU GX-5SUB/-8MUB/-12MUB/-30MUB
Cylindrical Inductive Proximity Sensor GX-U/GX-FU/GX-N
We can Supply all kinds of Panasonic sensor parts,such as Panasonic Micro Photoelectric Sensors,Panasonic Area Sensor,Panasonic Digital Fiber Sensor,Panasonic Fiber Sensor,Panasonic Laser Sensor,Panasonic Photoelectric Sensor,Panasonic Pressure Sensors and Panasonic Proximity Sensor.
Type | Shielded type | ||||
Type | Non-threaded type | Threaded type | |||
Normally open | GX-5SU | GX-8MU | GX-12MU | GX-18MU | GX-30MU |
Normally closed | GX-5SUB | GX-8MUB | GX-12MUB | GX-18MUB | GX-30MUB |
Max. operation distance (Note 2) | 1.5 mm 0.059 in ± 10 % | 2 mm 0.079 in ± 10 % | 3 mm 0.118 in ± 10 % | 7 mm 0.276 in ± 10 % | 10 mm 0.394 in ± 10 % |
Stable sensing range (Note 2) | 0 to 1.2 mm 0 to 0.047 in | 0 to 1.6 mm 0 to 0.063 in | 0 to 2.4 mm 0 to 0.094 in | 0 to 5.6 mm 0 to 0.220 in | 0 to 8 mm 0 to 0.315 in |
Standard sensing object | Iron sheet 6 x 6 x t 1 mm 0.236 x 0.236 x t 0.039 in | Iron sheet 8 x 8 x t 1 mm 0.315 x 0.315 x t 0.039 in | Iron sheet 12 x 12 x t 1 mm 0.472 x 0.472 x t 0.039 in | Iron sheet 18 x 18 x t 1mm 0.709 x 0.709 x t 0.0 39 in | Iron sheet 30 x 30 x t 1 mm 1.181 x 1.181 x t 0.039 in |
Hysteresis | 20 % or less of operation distance (with standard sensing object) | ||||
Supply voltage | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less | ||||
Current consumption (Note 3) | 0.8 mA or less | ||||
Output | Non-contact DC 2-wire type – Load current: 3 to 70 mA (Note 4) – Residual voltage: 3 V or less (Note 5) | ||||
Short-circuit protection | Incorporated | ||||
Max. response frequency | 1.7 kHz | 1.2 kHz | 1.2 kHz | 500 Hz | 350 Hz |
Operation indicator | Normally closed type: Orange LED (lights up when the output is ON) | ||||
2-color indicator | Normally open type: Lights up in green under stable sensing condition, lights up in orange under unstable sensing condition | ||||
Protection | IP67 (IEC), IP67G (Note 6) | ||||
Ambient temperature | -25 to +70 ℃ -13 to +158 ℉, Storage: -30 to +80 ℃ -22 to +176 ℉ | ||||
Ambient humidity | 45 to 85 % RH, Storage: 35 to 95 % RH | ||||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||||
Insulation resistance | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | ||||
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | ||||
Shock resistance | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | ||||
Material | Enclosure: Brass (Nickel plated) [Stainless steel (SUS303) for GX-5SU(B), GX-8MU(B) and GX-8MLU(B)] Sensing part: Nylon [Polyarylate for GX-5SU(B)], Indicator part: Nylon [excluding GX-5SU(B)] | ||||
Cable | 0.3 mm2 [0.15 mm2 for GX-5SU(B), GX-8MU(B) and GX-8MLU(B)] 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long | ||||
Cable extension | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | ||||
Weight (Note 7) | Net weight: 20 g approx. | Net weight: 30g approx. | Net weight: 55g approx. | Net weight: 95g approx. | Net weight: 220g approx. |
Accessories | – | Nut: 2 pcs., Toothed lock washer: 1 pc. |