| Availability: | |
|---|---|
Omron PLC CS1D-H CPU Unitas (pro Duplex CPU System) CS1D-CPU68HA/CPU67HA
Omron PLC Controller Module CP Series
Partes automationes Omron supplere possumus ut Omron PLC, Omron servo motori, Omron HMI, Omron VFD et Omron nullam et Omron sensorem.
MOQ: 1 pc
| Item | Specifications | |
| Imperium modum | Progressio stored | |
| I / O modum imperium | Scan cyclici et processus immediati ambo possibilis sunt. | |
| Programming |
• Scala describunt • SFC (sequential munus charts) • ST (structed text) • Mnemonics |
|
| Instructio longitudinem | I ad VII gradus per disciplinam | |
| scala instructiones | Proxime. CD (munus digiti 3-codes) | |
| Basic instructions | 0.02 ms min. | |
| Specialis instructiones | 0.04 ms min. | |
| Numerus operum |
288 (officia cyclica: 32, opera interrumpere: 256); Nota 1: Cyclica officia singulis cyclis exsecuta sunt et cum TKON (820) et TKOF (821) continentur, instructiones. 2: Sequentia 4 genera operum interrumpentium sustentantur. Potentia off interrumpenda negotia: 1 max. Scheduled pensa interregem: 2 max. I/O negotium in- terrupt: 32 max. Interpellare externa opera: 256 max. |
|
| Interpellare types |
Interrumpit: Interrupts generatur ad tempus a CPU Unit aedificatum in timer. I/O Interrumpit: Interrupts from Interrupt Input Unitates. Potestas OFF Interrumpit: Interrumpit supplicium cum potestas CPU Unit aversa est. Externus I/O Interrumpit: Interrumpit a Speciali I/O Unitates, CS-series CPU Bus Unitates, seu Tabula interior. |
|
| Munus caudices *1 | Linguae in functionibus clausulae definitiones: programmatio scalae, textus structi | |
| I / O Area |
5,120: CIO 000000 ad CIO 031915 (320 verba ab CIO 0000 ad CIO 0319) Occasio verbi primi mutari potest ex defectu (CIO 0000) ita ut CIO 0000 ad CIO 0999 adhiberi possit. I/O frena collocantur Basic I/O Unitates, ut CS-series Basic I/O Unitates, C200H Basic I/O Unitates, et C200H Group-2 Princeps densitas I/O Unitates. |
CIO Area adhiberi potest ut frena si frena non adhibeantur ut hic ostenditur. |
| Link Area | 3,200 ( verba 200): CIO 10000 ad CIO 119915 (verba CIO 1000 ad CIO 1199); Vincula pro data nexus adhibentur et ad Unitates partita sunt in Controller Link Systema et PLC Link Systema. |
|
| CPU bus Unit Area | 6,400 (verba 400): CIO 150000 ad CIO 189915 (verba CIO 1500 ad CIO 1899); CS-series CPU Bus Unitas frena reponunt statum operantem in CS-series CPU Bus Unitates. (25 words per Unit, 16 Unitates max.) |
|
|
Specialis I / O Area Unit |
15,360 (verba 960): CIO 200000 ad CIO 295915 (verba CIO 2000 ad CIO 2959); Specialis I/O Unitas frena partita sunt CS-series Specialis I/O Unitates et C200H Speciales I/O Unitates. (Vide Nota.) (X verba per Unit, 96 Unitates max. Maxima autem numerus foraminum ad LXXX inclusi cum foraminibus expansis limitatur, sic maximus numerus Unitarum 80 actu est. Nota: Maximum ex 16 C200H Speciali I/O Unitates ascendi possunt. Item, secundum unitates, maximum potest esse 10 . Pars I/O Unitates distinguuntur ut Speciales I/O Unitates. |
|
| Interiorem Area | 1,600 (verba 100): CIO 190000 ad CIO 199915 (verba CIO 1900 ad CIO 1999); Interior Tabula frena partita sunt tabulis interioribus. (C I/O verba max.) |
|
| SYSMAC BUS Area | 800 (50 verba): CIO 300000 ad CIO 304915 (verba CIO 3000 ad CIO 3049); SYSMAC BUS frena partita sunt servi eculei coniuncti SYSMAC BUS remotis I/O Magister Unitates. (10 words per Rack, 5 Racks max.) |
|
| I / O Area Terminal | 512 (32 verba): CIO 310000 ad CIO 313115 (verba CIO 3100 ad CIO 3131); I/O particulae terminales partitae sunt I/O Unitas Terminales (non autem Servi Racks) coniuncti SYSMAC BUS remotis I/O Magistro Unitates. (1 word per Terminal, 32 Terminal max.) |
|
| C200H Special I / O Area Unit | 8,192 bits (512 words): W00000 ad W51115 (W000 ad W511) C200H Specialis I/O Unitas frena ad C200H Speciales I/O Unitas partita sunt, et separatim accesserunt ab I/O refrigerio. |
|
| DeviceNet Area | 1,600 (verba 100): Outputs: CIO 00000 ad CIO 009915 (verba CIO 0050 ad CIO 0099) Inputs: CIO 035000 ad CIO 039915 (verba CIO 0350 ad CIO 0399) DeviceNet frena servis partita sunt secundum DeviceNet remotas I/O communicationes. |
|
| PLC Link Area | 64 bits (4 words): CIO 024700 ad CIO 025015 (verba CIO 0247 ad CIO 0250); Cum PLC Link Unit in a PLC Link adhibetur, his frenis utere ut monitor PLC Link errores et status operativus aliarum CPU Unitarum in PLC Link. |
|
| Internus I / O Area | 4,800 ( verba 300): CIO 120000 ad CIO 149915 (verba CIO 1200 ad CIO 1499); 37,504 verba (2,344): CIO 380000 ad CIO 614315 (verba CIO 3800 ad CIO 6143); Haec frena in CIO Area adhibentur ut frena laboris in programmandis programmatis executioni mandetur. (Non possunt externa I / O). |
|
| Area Opus | 8,192 bits (512 words): H00000 ad (H000 to) Haec frena in CIO Area adhibentur ut frena laboris in programmandis programmatis executioni mandetur. (Non possunt externa I / O). Cum frenos in programmando utendo, frenos in Area Laboris utere prius quam frenis ex aliis locis utere. |
|
| Area tenentes |
8,192 bits (512 words): H00000 ad (H000 to) Frena tenentes executionem programmatis moderari solent, eorum DE/OFF statum conservant cum PLC deflectitur vel mutatur modus operandi. Nota: Munus Clausus obtinens Area verba ab H512 ad H1535 partita sunt. Haec verba nonnisi ad functionem clausulae instantiae areae (interne variabilis area collocantur). |
|
| Auxiliaris Area | Lege tantum: 7,168 frena (448 verba): A00000 ad A44715 (verba A000 ad A447) Lege/ scribe: 8,192 frena (512 verba): A44800 ad A95915 (verba A448 ad A959) frena auxiliaria certae functiones collocantur. | |
| Tempus Area | XVI bits (TR0 ad TR15) Temporaria frena ad tempus DE/OFF executioni condiciones in ramis programmatis reponunt. |
|
| Timer Area | 4,096: T0000 ad T4095 (separatum ab calculis) Nota: unitates temporis ad occasus timentis sunt 0.1 s, 0.01 s, et 0.001 s (prout instructionis timoris quae adhibetur). |
|
| Contra Area | C0000 ad C4095 (separatum a timers) | |
|
DM Area |
32K verba: D00000 ad D32767 Internum Praecipuum I/O Unit DM Area: D20000 ad D29599 (100 verba x 96 Unitas) Solebant parametri constituere pro Speciali I/O Unitates. CPU bus Unit DM Area: D30000 ad D31599 (C verba x 16 Unitates) Solebant parametri CPU bus Unitates collocare. Interior Board DM Area: D32000 ad D32099 Solebant parametri pro tabulis interioribus. Adhibetur ut generalis propositi notitia area ad legendi et scribendi notitias in verbo unitatum (16 bits). Verba in DM Area conservant statum suum cum PLC vertitur Off seu modus operandi mutatur. |
|